Your browser is out of date.

You are currently using Internet Explorer 7/8/9, which is not supported by our site. For the best experience, please use one of the latest browsers.

685I Visual Liquid Level Indicator for Atmospheric Vessels

The Model 685I is a liquid head pressure type level indicator. It continuously indicates the liquid level in an atmospheric (vented) tank in feet and inches. Also, the scale on the Model 685I is available calibrated for horizontal cylindrical vessels in pounds, gallons, barrels, percent, etc.

Contact an expert
685I Visual Liquid Level Indicator for Atmospheric Vessels
Operation

Liquid head pressure against a flexible elastomer diaphragm is transmitted directly to a leaf spring, which has a fixed pivot point at the upper end and an adjustable fulcrum point in the mid region of the leaf spring. For example, because 8’ of heavy liquid exerts more pressure on the diaphragm than 8’ of lighter liquid, the spring can be “stiffened” by moving the fulcrum down by the gravity adjustment knob (red), so the indicator will still read 8’. The zero knob (green) moves the entire spring assembly and pointer, having the same effect as shifting the scale.

Installation

Since the unit measures liquid head pressure, the point at which it is installed on the vessel is the point that liquid measurement begins. For calibration and maintenance purposes, always install an isolation valve between the model 685I and the vessel. Also, install a drain petcock in the liquid inlet bottom, where a plug is generally located.

Features

  • Simple Adjustments: Zero Adjustment Knob and one Specific Gravity (span) Knob. Unit can be factory calibrated for a nominal cost or field adjusted in less than 15 minutes, without having to change the liquid level in the vessel.
  • Easy to Read: Scale reads the same as a hand tank gauge, making it unnecessary to convert psig of head pressure into feet and inches of liquid to get the correct reading.
  • Long Life: All bearings are Teflon®, Delrin® or Moly Disulphide baked on Dry Film Lubricated Stainless Steel.

Specifications

  • Indicator Housing: Weatherproof
  • Proof Pressure: 100 psig
  • Temperature: -20˚F to +225˚F Standard
  • Pressure: 0 to 4 ounces pressure (Atmospheric)
  • Range (Vessel Height): 3’ thru 60’ (see 685 code sheet)

Why work with us

7,300+

Employees

60+

Countries

40+

Manufacturing Locations

400+

Scientists and Technologists